Difference between revisions of "TUFLOW Message 2065"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Unresolvable connections to 1D Nodes.
+
|message_desc=This error can occur when two CN lines are snapped to the same HX vertex.
|suggestions=Contact support@tuflow.com.
+
|suggestions=Create additional vertex on the HX line and snap one of the CN lines to this vertex instead. Otherwise, contact support@tuflow.com.
 
|discussion_page=* [[Talk:TUFLOW Message 2065|Discuss Message 2065]]
 
|discussion_page=* [[Talk:TUFLOW Message 2065|Discuss Message 2065]]
 
|link3=''
 
|link3=''

Revision as of 15:18, 14 August 2020

TUFLOW Message
ERROR 2065 - Unresolvable connections to 1D Nodes: "a",

Alternate Message
NA

Message Type
ERROR

Description
This error can occur when two CN lines are snapped to the same HX vertex.

Suggestions
Create additional vertex on the HX line and snap one of the CN lines to this vertex instead. Otherwise, contact support@tuflow.com.


Up