Difference between revisions of "Tutorial M06"

From Tuflow
Jump to navigation Jump to search
Line 123: Line 123:
 
<li>Update the Rainfall Losses column for Material 1D 1 (pasture) and 10 (vegetated creek) with an initial loss of 20mm and continuing loss of 5mm/hr:<br>
 
<li>Update the Rainfall Losses column for Material 1D 1 (pasture) and 10 (vegetated creek) with an initial loss of 20mm and continuing loss of 5mm/hr:<br>
 
<br>
 
<br>
[[File:M06 Materials 002.png]]<br>
+
[[File:M06 Materials 002a.png]]<br>
 
<br>
 
<br>
 
<li>Save the materials file.
 
<li>Save the materials file.

Revision as of 10:42, 16 November 2022

Introduction

In this module, a direct rainfall model is built. The tutorial demonstrates three ways of modelling rainfall for a direct rainfall approach.

  • Part 1: Global Rainfall - apply uniform rainfall to all active cells.
  • Part 2: Rainfall Polygons - apply rainfall to active cells within digitised polygons and losses within the materials layer.
  • Part 3: Gridded Rainfall - apply rainfall temporally and spatially using a TUFLOW Rainfall Control File (TRFC).

The GIS layers are:

  • TBC layers:
    1. 2d_rf: polygons are assigned a rainfall gauge and spatial and temporal adjustment factors.
  • TRFC layers:
    1. 2d_rf: points are specified reflecting rainfall gauge locations. Rainfall is interpolated and a series of rainfall grids are generated.

Module 6 builds from the model created in Module 2. The completed Module 2 model is provided in the Module_06\TUFLOW folder.

Part 1 - Global Rainfall

Boundary Condition Database (bc_dbase)

Update the bc_dbase with a reference to the new rainfall hyetographs:

  1. Navigate to the Module_06\Tutorial_Data folder. Copy the rainfall_stations.csv and paste it in the Module_06\TUFLOW\bc_dbase folder. This file contains the rainfall hyetographs.
  2. Open the file, there are 4 columns labelled ‘RF_FC04’ to ‘RF_FC07’. Part 1 references 'RF_FC04', the remaining hyetographs are used in Part 2.

    M06 hyetograph.png

  3. Save a copy of the bc_dbase.csv as bc_dbase_M06_001.csv.
  4. Open the file and add the additional rainfall boundary conditions:

    M06 bc dbase 01a.png

  5. Save the bc_dbase.

Materials

Surface roughness or bed resistance values (e.g. Manning’s n) are assigned to material IDs. Depth varying roughness values are used in direct rainfall models to reflect the bed roughness at shallow depths.

  1. Copy the materials_M06_001.csv file from the Module_06\Tutorial_Data folder into the Module_06\TUFLOW\model folder. Depth-varying roughness values are applied to three of the Material IDs within the study area:

    M06 Materials 001.png

  2. For Material ID 1, 3 and 5, four numbers (y1, n1, y2, n2) are added to each row separated by commas and are applied as follows:
    • Below depth y1 (m), a Manning’s n value of n1 is applied,
    • Above depth y2 (m), a Manning’s n value n2 is applied, and
    • Between y1 and y2, the Manning’s n value is interpolated between n1 and n2. The default interpolation method uses a curved fit so that the n values transition gradually.
  3. For example, for Material ID 1, for depths of water below 0.03m a Manning's n value of 0.10 is applied. For depths of water greater than 0.1m, a Manning's n value of 0.06 is applied. Between 0.03 to 0.1m, a Manning's n value is interpolated between 0.1 and 0.06.
  4. For Material ID 2 and 4, the Manning’s n value specified in the second column will be applied at all depths, i.e. a value of 0.022 for Material ID 2.

Simulation Control Files

TUFLOW Boundary Control File (TBC)

  1. Save a copy of M01_001.tbc as M06_001.tbc in the Module_06\TUFLOW\model folder.
  2. Open the M06_001.tbc in a text editor.
  3. The current rainfall versus time inflows (2d_sa) are replaced in this tutorial. The base inflow and outflow (2d_bc) remain the same. Comment out the 'Read GIS SA' command by placing '!' at the beginning:
    ! Read GIS SA == gis\2d_sa_M01_001_R.shp
  4. Add the following command line:
    Global Rainfall BC == RF_FC04 ! Reads in global rainfall
  5. Save the TBC.

The Global Rainfall BC command applies a rainfall depth to every active cell within the 2d_code layer based on the input hyetograph. In this case it is the 'RF_FC04' hyetograph specified in the rainfall_stations.csv. The input hyetograph must be in mm verse time, and is applied using a stepped approach. The stepped approach holds the rainfall constant for the time interval (i.e. the rainfall has a histogram stair-step shape). This means, for example, the second rainfall value in the time-series is applied as a constant rainfall from the first time value to the second time value. As with all rainfall boundaries, the first and last rainfall entries should be set to zero, otherwise these rainfall values are applied as a constant rainfall if the simulation starts before or extends beyond the first and last time values in the rainfall time-series.

TUFLOW Control File (TCF)

  1. Save a copy of M02_5m_001.tcf as M06_5m_001.tcf in the Module_06\TUFLOW\runs folder.
  2. Open the M06_5m_001.tcf in a text editor and update the reference of the TBC:
    BC Control File == ..\model\M06_001.tbc  ! Reference the TUFLOW Boundary Conditions Control File
  3. Update the reference to the bc database:
    BC Database == ..\bc_dbase\bc_dbase_M06_001.csv  ! Reference the Boundary Conditions Database
  4. Update the reference to the materials file:
    Read Materials File == ..\model\materials_M06_001.csv  ! Reference the Materials Definition File
  5. A Timestep Maximum command is required in direct rainfall modelling to ensure the timestep does not get too large during periods where cells are dry (causing the model to become unstable). Include the following command in the ! TIME CONTROL section:
    Timestep Maximum == 5 ! Specifies a maximum timestep of 5 seconds
  6. Add Cumulative Rainfall (RFC), Rainfall Rate (RFR) and Manning's n (n) as additional Map Output Data Types. These outputs are discussed in the Results section.
    Map Output Data Types == h V d dt RFC RFR n ! Outputs water levels, velocities, depths, minimum timestep, cumulative rainfall, rainfall rate, manning's n
  7. A Map Cutoff Depth is useful for direct rainfall modelling where there is a need to differentiate between very shallow sheet flow and flooding. Include the following command in the ! OUTPUT SETTINGS section:
    Map Cutoff Depth == 0.1 ! Sets map cutoff depth of 0.1 meters
  8. Save the TCF.

Running the Simulation

  1. Save a copy of _run_M02_HPC.bat as _run_M06_HPC.bat in the Module_06\TUFLOW\runs folder.
  2. Update the batch file to reference the M06_5m_001.tcf :
    set exe="..\..\..\exe\2020-10-AF\TUFLOW_iSP_w64.exe"
    set run=start "TUFLOW" /wait %exe% -b
    %run% M06_5m_001.tcf
  3. Save the batch file and double click it in file explorer to run the simulation.

Troubleshooting

See tips on common mistakes and troubleshooting steps if the model doesn't run:

Check Files

While the model is running, review the added features are specified correctly:

  1. Open the M06_5m_001.tlf from the Module_06\TUFLOW\runs\log folder in a text editor.
  2. Review the hyetograph information. When using the direct rainfall approach, a rainfall depth fallen in a particular increment of time is input. TUFLOW converts this depth per time increment to a flow (m3/s) and applies this flow at each cell. The TLF shows this conversion:

    M06 histogram conversion.png

Results

When the model is finished, review the results:


Part 2 - Rainfall Polygons

The second part of this module introduces:

  • Polygons in a 2d_rf file to distribute multiple hyetographs across the catchment.
  • Initial and continuing rainfall losses in the materials file.

GIS Inputs

Create, import and view input data:

Materials

Rainfall losses applied through the materials file remove the loss depth from the rainfall before it is applied as a boundary on the 2D cells.

  1. Save a copy of materials_M06_001.csv as materials_M06_002.csv in the Module_06\TUFLOW\model folder.
  2. Open the materials_M06_002.csv in a spreadsheet program.
  3. Update the Rainfall Losses column for Material 1D 1 (pasture) and 10 (vegetated creek) with an initial loss of 20mm and continuing loss of 5mm/hr:

    M06 Materials 002a.png

  4. Save the materials file.

Simulation Control Files

TUFLOW Boundary Control File (TBC)

  1. Save a copy of M06_001.tbc as M06_002.tbc in the Module_06\TUFLOW\model folder.
  2. Open the M06_002.tbc in a text editor.
  3. Comment out the Global Rainfall command and add the Read GIS RF command:
    ! Global Rainfall BC == RF_FC04
    Read GIS RF == gis\2d_rf_M06_polygons_002_R.shp ! Reads in 2D rainfall boundaries
  4. Save the TBC.

TUFLOW Control File (TCF)

  1. Save a copy of M06_5m_001.tcf as M06_5m_002.tcf in the Module_06\TUFLOW\runs folder.
  2. Open the M06_5m_002.tcf in a text editor and update the reference of the TBC:
    BC Control File == ..\model\M06_002.tbc  ! Reference the TUFLOW Boundary Conditions Control File
  3. Update the reference to the materials file:
    Read Materials File == ..\model\materials_M06_002.csv  ! Reference the Materials Definition File
  4. Add Material Rainfall Loss (RFML) as an additional Map Output Data Type. This output is discussed in the Results section.
    Map Output Data Types == h V d dt RFC RFR RFML ! Outputs water levels, velocities, depths, minimum timestep, cumulative rainfall, rainfall rate, material based rainfall loss
  5. Save the TCF.

Running the Simulation

Update the batch file created in the first part of Module 6 to reference the M06_5m_002.tcf file. Save the batch file and double click it in file explorer to run the simulation.

Troubleshooting

See tips on common mistakes and troubleshooting steps if the model doesn't run:

Check Files

While the model is running, review the added features are specified correctly:

  1. Open the M06_5m_002.tlf from the Module_06\TUFLOW\runs\log folder in a text editor.
  2. Review the losses applied in the materials layer:

    Animation M06 Check 002 01.gif

  3. Review the hyetograph information. The TLF shows the conversion for each histogram:

    Animation M06 Check 002 02.gif

Results

When the model is finished, review the results:


Part 3 - Rainfall Control File

GIS Inputs

Create, import and view input data:

Simulation Control Files

TUFLOW Rainfall Control File (TRFC)

The TRFC commands generate rainfall grids based on point rainfall gauges. There are three spatial interpolation methods available, this tutorial uses Inverse Distance Weighting (IDW). For more information on IDW and the other available methods, see Section 7.4.3.4 of the 2018 TUFLOW Manual.
The TRFC is processed during model initialisation, outputting a series of rainfall grids which are used by the simulation to vary the rainfall over the 2D domain. The rainfall grids are output to a separate folder RFG\<TCF name> in the location of the TRFC (e.g. Module_06\TUFLOW\model\RFG\M06_5m_003). This approach reduces memory usage while TUFLOW is running.

  1. Create a new text file M06_point2grid_003.trfc and save it in the Module_06\TUFLOW\model folder.
  2. Add the following commands:
    RF Grid Format == FLT  ! Sets the output grid format
    RF Interpolation Method == IDW  ! Sets the interpolation approach between rainfall locations
    RF Grid Cell Size == 25  ! Sets the cell size for the generated rainfall grids
    Read GIS RF Points == gis\2d_rf_M06_pt2grid_003_P.shp  ! Reads the point rainfall locations in the 2d_rf file format
  3. Save the TRFC.

TUFLOW Boundary Control File (TBC)

  1. Save a copy of M06_002.tbc as M06_003.tbc in the Module_06\TUFLOW\model folder.
  2. Open the M06_003.tbc in a text editor and comment out the Read GIS RF command:
    ! Read GIS RF == gis\2d_rf_M06_polygons_002_R.shp
  3. Save the TBC.

TUFLOW Control File (TCF)

  1. Save a copy of M06_5m_002.tcf as M06_5m_003.tcf in the Module_06\TUFLOW\runs folder.
  2. Open the M06_5m_003.tcf in a text editor and update the reference of the TBC:
    BC Control File == ..\model\M06_003.tbc  ! Reference the TUFLOW Boundary Conditions Control File
  3. Include a reference to the TRFC:
    Rainfall Control File == ..\model\M06_point2grid_003.trfc ! Reference the TUFLOW Rainfall Control File
  4. Save the TCF.

Running the Simulation

Update the batch file to reference the M06_5m_003.tcf file. Save the batch file and double click it in file explorer to run the simulation.

Troubleshooting

See tips on common mistakes and troubleshooting steps if the model doesn't run:

Check Files

While the model is running, review the added features are specified correctly:

  • Navigate to the Module_06\TUFLOW\model\RFG\M05_5m_003 folder with rainfall grids created from the rainfall interpolation.
  • The timestep matches the one specified in the rainfall hyetographs (10 minutes). Hours are used in the rainfall grids names:
    M06 RFG grids 01.png


  • A total rainfall depth M06_5m_003_rf_total.flt is created, this is not used by TUFLOW during the simulation, but can be used for checking purposes.

    M06 rf total 01.png

Results

When the model is finished, review the results:


Conclusion

  • Direct rainfall approach was used in three ways - applied globally, to separate polygons using 2d_rf layer and varying temporally and spatially using a TUFLOW Rainfall Control (TRFC).
  • Rainfall losses were applied in the materials layer.
  • TUFLOW log files and rainfall grids were used to check the rainfall was applied correctly.
  • Map outputs RFC, RFR and RFML were inspected.


Gridded Rainfall (Optional)

The rainfall grids created from the rainfall interpolation and located in the Module_06\TUFLOW\model\RFG\M06_5m_003 folder can be used by the Read Grid RF command in the TCF to apply the rainfall to the model, rather than regenerate the rainfall grids using the TRFC file (as long as the input files remain unchanged). The command references a csv file containing links to the rainfall grids.

  1. Navigate to the Module_06\Tutorial_Data folder. Copy the M06_004_rf.csv into the Module_06\TUFLOW\bc_dbase folder.
  2. Open the csv. The file requires two columns, the first is time (in simulation hours) and the second is the rainfall grid.

    M06 griddedrainfall 01.png

  3. Save a copy of M06_5m_003.tcf as M06_5m_004.tcf. Change the commands to read in the grids created in the RFG folder:
    ! Rainfall Control File == ..\model\M06_point2grid_003.trfc ! Reference the Rainfall Control File
    Read Grid RF == ..\bc_dbase\M06_004_rf.csv
  4. Save the TCF and run the model.
  5. Compare the results with the Part 3 results.
  6. Check the run times in the _ TUFLOW Simulations.log from the TUFLOW\runs folder. For large models, the initialisation time is faster with the gridded rainfall set up.


Up
Go-up.png Back to Tutorial Introduction Main Page