Difference between revisions of "TUFLOW Message 2030"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by one other user not shown)
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
 
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
|suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries.
+
|suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The <u>[[Check_Files_2d_bcc_check | bcc_check]]</u> layer is useful identifying cells acting as boundaries.
 +
 
  
|prelink=[[TUFLOW_Message_2029|Message 2029]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2031|Message 2031]]
 
 
}}
 
}}

Latest revision as of 11:00, 23 December 2022

TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.

Alternate Message
NA

Message Type
ERROR

Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).

Suggestions
Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries.


Up
Go-up.png 2xxx Messages