Difference between revisions of "TUFLOW Message 1033"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1033 - No XS line data downstream of channel ",a,". Could not interpolate cross-section properties. |alt_msg=ERROR 1033 - No XS line data ...')
 
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 1033 - No XS line data downstream of channel ",a,".  Could not interpolate cross-section properties.
+
|tuflow_message=ERROR 1033 - No XS line data downstream of channel "XXXX".  Could not interpolate cross-section properties.
|alt_msg=ERROR 1033 - No XS line data upstream of channel ",a,".  Could not interpolate cross-section properties.
+
|alt_msg=ERROR 1033 - No XS line data upstream of channel "XXXX".  Could not interpolate cross-section properties.
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=Cross-Sectional data for the channel named "XXXX" cannot be found.
|suggestions=????
+
|suggestions=Each channel requires a table describing its hydraulic properties to define its conveyance.  The properties are normally defined by digitising a cross-section in a 1d_tab layer positioned midway along the channel or at the channel ends. the 1d_tab layer references an external csv file (or similar formatted file) containing either a cross-section profile or a hydraulic properties table. The hydraulic properties can also be externally sourced from a Mike 11 or ISIS model. Note that structures such as culverts and weirs, are an exception to the rule. The attribute information supplied within the 1d_nwk table are sufficient to define the hydraulic properties. <br>
 +
<br>
 +
Refer to section 4.6 of the 2010 TUFLOW Manual for more information. For detailed instructions on setting up the 1d_nwk and 1d_tab layers, refer to Module 4 of the Tutorial model. <br>
 +
 
 
|discussion_page=* [[Talk:TUFLOW Message 1033|Discuss Message 1033]]
 
|discussion_page=* [[Talk:TUFLOW Message 1033|Discuss Message 1033]]
 
|link3=''
 
|link3=''

Revision as of 15:17, 21 October 2014

TUFLOW Message
ERROR 1033 - No XS line data downstream of channel "XXXX". Could not interpolate cross-section properties.

Alternate Message
ERROR 1033 - No XS line data upstream of channel "XXXX". Could not interpolate cross-section properties.

Message Type
ERROR

Description
Cross-Sectional data for the channel named "XXXX" cannot be found.

Suggestions
Each channel requires a table describing its hydraulic properties to define its conveyance. The properties are normally defined by digitising a cross-section in a 1d_tab layer positioned midway along the channel or at the channel ends. the 1d_tab layer references an external csv file (or similar formatted file) containing either a cross-section profile or a hydraulic properties table. The hydraulic properties can also be externally sourced from a Mike 11 or ISIS model. Note that structures such as culverts and weirs, are an exception to the rule. The attribute information supplied within the 1d_nwk table are sufficient to define the hydraulic properties.

Refer to section 4.6 of the 2010 TUFLOW Manual for more information. For detailed instructions on setting up the 1d_nwk and 1d_tab layers, refer to Module 4 of the Tutorial model.