Difference between revisions of "TUFLOW Message 1313"
Line 4: | Line 4: | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
|message_desc=1D manhole object is not snapped to a inlet or outlet culvert. Manhole not being used. | |message_desc=1D manhole object is not snapped to a inlet or outlet culvert. Manhole not being used. | ||
− | |suggestions=Ensure manhole is snapped in valid location with 1D culverts upstream and downstream of the manhole. | + | |suggestions=Ensure manhole is snapped in valid location with 1D culverts upstream and downstream of the manhole. <br> |
+ | <br> | ||
+ | This warning is expected when any inlet pipe has an invert above the highest soffit of all output pipes. The pipe with high invert is ignored when determining manhole losses because it is essentially hydraulically disconnected. The full exit loss (if d/s controlled) or free-outflow (if not d/s controlled) is applied to the elevated inlet pipe. | ||
|discussion_page=* [[Talk:TUFLOW Message 1313|Discuss Message 1313]] | |discussion_page=* [[Talk:TUFLOW Message 1313|Discuss Message 1313]] | ||
|link3='' | |link3='' |
Revision as of 16:52, 8 October 2019
TUFLOW Message
WARNING 1313 - No inlet culvert connected to Manhole ",a,". Manhole not used/applied.
Alternate Message
WARNING 1313 - No outlet culvert connected to Manhole ",a,". Manhole not used/applied.
Message Type
WARNING
Description
1D manhole object is not snapped to a inlet or outlet culvert. Manhole not being used.
Suggestions
Ensure manhole is snapped in valid location with 1D culverts upstream and downstream of the manhole.
This warning is expected when any inlet pipe has an invert above the highest soffit of all output pipes. The pipe with high invert is ignored when determining manhole losses because it is essentially hydraulically disconnected. The full exit loss (if d/s controlled) or free-outflow (if not d/s controlled) is applied to the elevated inlet pipe.
Up |
---|
1xxx Messages |