TUFLOW Message 2347
Revision as of 10:14, 18 July 2022 by Melissa.Moghanloo (talk | contribs)
TUFLOW Message
ERROR 2347 - Insufficient header information in ASCII grid file [Location]. Check format of file.
Alternate Message
NA
Message Type
ERROR
Description
When processing a Read Grid Location == , the .asc format file is missing key data. The top lines of the .asc file contain information about the location and size of the .asc grid. For example:
ncols 100 nrows 100 xllcorner 1000 yllcorner 3000 cellsize 1 NODATA_value -9999
If data is missing from this, Error 2347 may occur.
Suggestions
Check .asc file is valid and contains all header information.
Alternatively, use a different method for defining the model location, such as .tgc commands Origin, Orientation Angle, Grid Size or Read GIS Location
Up |
---|