Difference between revisions of "TUFLOW Message 1262"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[WARNING]]
 
|type=[[WARNING]]
|message_desc=????
+
|message_desc=Manning's n value assigned to channel, is outside normal range.
|suggestions=????
+
|suggestions=Check Manning's n value for channel.  If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Mannings value (e.g. 0.04) and materials are defined in the XZM cross-section.  In this case the Mannings n value may become 0.04 x 0.04 = 0.0016!
 
|discussion_page=* [[Talk:TUFLOW Message 1262|Discuss Message 1262]]
 
|discussion_page=* [[Talk:TUFLOW Message 1262|Discuss Message 1262]]
 
|link3=''
 
|link3=''

Revision as of 09:32, 2 February 2011

TUFLOW Message
WARNING 1262 - Manning's n value of ",a," for channel ",a," is unusually low or high.

Alternate Message
NA

Message Type
WARNING

Description
Manning's n value assigned to channel, is outside normal range.

Suggestions
Check Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). This can occur if a the multiplication value is set to a typical Mannings value (e.g. 0.04) and materials are defined in the XZM cross-section. In this case the Mannings n value may become 0.04 x 0.04 = 0.0016!


Up
Go-up.png 1xxx Messages