|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit.  Flows from 2D HX cells can only be assigned to ISIS RIVER units.<BR>
 
|alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit.  Flows from 2D HX cells can only be assigned to ISIS RIVER units.<BR>
 
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
 
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
|type=[[ERROR]]
+
|type=[[ERROR]]<br>
 
[[WARNING]]
 
[[WARNING]]
 
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.
 
|message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.

Revision as of 16:52, 18 October 2018

TUFLOW Message
ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.

Alternate Message
ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.
WARNING 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.

Message Type
ERROR
WARNING

Description
2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.

Suggestions
Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.
Since TUFLOW built 2018-03-AC this error can be changed into warning by using command SX FMP Unit Type Error == OFF.