TUFLOW Message 3038

From Tuflow
Revision as of 10:17, 20 April 2018 by Teegan.Burke (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3038: Flow width factors must be >= 0. <br> |alt_msg=None |type=ERROR |message_desc=The value of specified Cell Width Factor must...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 3038: Flow width factors must be >= 0.

Alternate Message
None

Message Type
ERROR

Description
The value of specified Cell Width Factor must be greater than 0.0.

Suggestions
The Cell Width Factor can be used to adjust the 2D cell flow widths. It is a factor, for example 0.1 will limit the flow width to 10%. The changed flow width applies to all depths. When reading from a polygon object in GIS format, any cell sides that fall within the polygon will have the width factor applied. These factors can be reviewed within the uvpt_check file.


Up
Go-up.png 3xxx Messages