Integrity Tool - Flow Trace Tool

From Tuflow
Jump to navigation Jump to search

The Flow Trace tool creates traces upstream from the selected channel, selecting all upstream network objects in the QGIS map window (network lines and network points).

  1. Find and select link Pipe15.
    Pipe15.png
  2. Ensure that 1d_nwk_MI01_Pipes_001_L_EG1_ID1_SN1_PD1 is referenced in the 1D network Line Layers and select the Flow Trace tab.
  3. Select the relevant option to undertake the Flow Area and the Invert Checks.
  4. Also ensure the ‘Generate Long plots’ option is selected.
    Flow trace.png
    Table 1 describes the various Checks that can be conducted.

    Table 1: Flow Trace Checks
    Check Description
    Flow Area Check Identifies location where the downstream flow are decreases
    Invert Check Identifies location where pipes have either an adverse gradient or where the outgoing pipe invert level is higher than the incoming pipe invert.
    Angle Check Identify locations where the angle between incoming and outgoing pipe is less than a given input angle (180 degrees is straight)
    Ground Cover Check Identifies locations where the distance between the pipe suffix and the ground elevation (taken from an in input DTM) is less than specified
  5. Run the Flow Trace. This will select all the upstream links and also add another output layer identifying the locations which fail the flow area and invert checks.
    Flow trace output.png
    A Flow Trace window is also provided which provides long sections or the various upstream paths from the selected link, highlighting areas of continuity failures. The individual paths can be assessed individually and identified within the QGIS canvas.
    Flow trace canvas.png
    To find out more about the options in the Flow Trace Canvas see this page.
    In this instance the identified issues would have to manually adjusted if appropriate, no automatic fixes are available.

Please return to the 1D Integrity tutorial page to continue the tutorial.