TUFLOW Message 1462
Revision as of 01:07, 29 November 2024 by ElizaCollison (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries. |alt_msg=NA<br> |type=ERROR |message_desc=A 1D node wit...")
TUFLOW Message
ERROR 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries.
Alternate Message
NA
Message Type
ERROR
Description
A 1D node within the model has been connected to both a 2D SX and a 2D HX boundary. A node should only be connected to one of the boundary types.
Suggestions
Reconfigure the model to ensure the 1D node is connected to either a SX boundary OR a HX boundary. The _messages GIS layer spatially displays which node is triggering this error.
Up |
---|