TUFLOW Message 2663

From Tuflow
Revision as of 00:40, 27 June 2026 by Ellis Symons (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 2663 - Disabling temporal output due to GLO output.

Alternate Message
N/A

Message Type
ERROR

Description
Gauge level outputs (GLO) replace the conventional approach of using a "Start Map Output" time and "Map Output Interval" (i.e. it is not possible to get map outputs using a gauge location and also at a regular intervals).

Suggestions
Remove the "Read GIS GLO" command if map outputs at a regular interval are desired.


Up
2xxx Messages