Difference between revisions of "TUFLOW Message 1104"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Diameter for circular culvert (C type channel) is less than or equal to zero.
 
|message_desc=Diameter for circular culvert (C type channel) is less than or equal to zero.
|suggestions=Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0.  This diameter is in metres.
+
|suggestions=Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0.  This diameter is in metres, not mm!
 
|discussion_page=* [[Talk:TUFLOW Message 1104|Discuss Message 1104]]
 
|discussion_page=* [[Talk:TUFLOW Message 1104|Discuss Message 1104]]
 
|link3=''
 
|link3=''

Revision as of 16:20, 31 January 2011

TUFLOW Message
ERROR 1104 - Diameter of C culvert is less than or equal to zero.

Alternate Message
NA

Message Type
ERROR

Description
Diameter for circular culvert (C type channel) is less than or equal to zero.

Suggestions
Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0. This diameter is in metres, not mm!


Up
Go-up.png 1xxx Messages