TUFLOW Message 1105: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Width and/or height of rectangular culvert(R type channel) is less than or equal to zero. |
|message_desc=Width and/or height of rectangular culvert (R type channel) is less than or equal to zero. |
||
|suggestions=Enter a valid width into Width_or_Dia and a height into Height_or_WF GIS attributes. These are fields 14 and 15 in 1d_nwk layer, values in metres. |
|suggestions=Enter a valid width into Width_or_Dia and a height into Height_or_WF GIS attributes. These are fields 14 and 15 in 1d_nwk layer, values in metres. |
||
|discussion_page=* [[Talk:TUFLOW Message 1105|Discuss Message 1105]] |
|discussion_page=* [[Talk:TUFLOW Message 1105|Discuss Message 1105]] |
||
Revision as of 16:22, 31 January 2011
TUFLOW Message
ERROR 1105 - Width and/or height of R culvert is less than or equal to zero.
Alternate Message
NA
Message Type
ERROR
Description
Width and/or height of rectangular culvert (R type channel) is less than or equal to zero.
Suggestions
Enter a valid width into Width_or_Dia and a height into Height_or_WF GIS attributes. These are fields 14 and 15 in 1d_nwk layer, values in metres.