Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1117 - Invalid Conn_2D attribute at pit or node. Cannot exceed 3 characters. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=?...' |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:<br> |
|||
|message_desc=???? |
|||
SX<br> |
|||
|suggestions=???? |
|||
SXL<br> |
|||
SXZ<br> |
|||
SXG<br> |
|||
SXS<br> |
|||
For a detalied description of these options see Section 4.5.1.3 Connecting Pits and Nodes to 2D Domains and Table 4.14 1D model Network (1d_nwk) Attribute Descriptions of the TUFLOW manual (2010 version). |
|||
|suggestions=Specify a valid attribute as per the list above. |
|||
|discussion_page=* [[Talk:TUFLOW Message 1117|Discuss Message 1117]] |
|discussion_page=* [[Talk:TUFLOW Message 1117|Discuss Message 1117]] |
||
|link3='' |
|link3='' |
||
Revision as of 08:34, 1 February 2011
TUFLOW Message
ERROR 1117 - Invalid Conn_2D attribute at pit or node. Cannot exceed 3 characters.
Alternate Message
NA
Message Type
ERROR
Description
An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:
SX
SXL
SXZ
SXG
SXS
For a detalied description of these options see Section 4.5.1.3 Connecting Pits and Nodes to 2D Domains and Table 4.14 1D model Network (1d_nwk) Attribute Descriptions of the TUFLOW manual (2010 version).
Suggestions
Specify a valid attribute as per the list above.