Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1208 - Reading node network data. Check 1d_nwk layer has correct attributes. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=?...' |
No edit summary |
||
Line 3:
|alt_msg=NA
|type=[[ERROR]]
|message_desc=An error has occurred whilst reading 1d network data (1d_nwk). Check that the attributes of the layer match those in the Table 4.14 (1D Model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version). An empty 1d_nwk file is written with the <tt>Write Empty MI Files == </tt> tcf command.
|suggestions=Ensure the layer has the correct attributes and ensure that the <tt>Read GIS Network == </tt> is only for network data and not 1d boundary or table links.
|discussion_page=* [[Talk:TUFLOW Message 1208|Discuss Message 1208]]