Difference between revisions of "TUFLOW Message 0116"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0. |alt_msg=NA |type=ERROR |message_desc=????...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=First data pair for pit inlet curve (depth-flow) are not 0,0.  The first values must be 0 (at depth 0) and 0 (flow is zero). Anything  else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m<sup>3</sup>/s is generated, and mass is created!
|suggestions=????
+
|suggestions=Ensure first values in inlet curve are 0,0
 
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]]
 
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]]
 
|link3=''
 
|link3=''

Revision as of 19:10, 6 February 2011

TUFLOW Message
ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0.

Alternate Message
NA

Message Type
ERROR

Description
First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m3/s is generated, and mass is created!

Suggestions
Ensure first values in inlet curve are 0,0