TUFLOW Message 0116: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0. |alt_msg=NA |type=ERROR |message_desc=????...'
 
No edit summary
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m<sup>3</sup>/s is generated, and mass is created!
|message_desc=????
|suggestions=????
|suggestions=Ensure first values in inlet curve are 0,0
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]]
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]]
|link3=''
|link3=''

Revision as of 19:10, 6 February 2011

TUFLOW Message
ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0.

Alternate Message
NA

Message Type
ERROR

Description
First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m3/s is generated, and mass is created!

Suggestions
Ensure first values in inlet curve are 0,0


Up