TUFLOW Message 2215: Difference between revisions
		
		
		
		Jump to navigation
		Jump to search
		
Content deleted Content added
|  Created page with '{{TUFLOW_Message |tuflow_message=WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object. |alt_msg=NA |type=WARNING |message_desc=???? |suggestions=???? |discuss...' | No edit summary | ||
| Line 3: | Line 3: | ||
| |alt_msg=NA | |alt_msg=NA | ||
| |type=[[WARNING]] | |type=[[WARNING]] | ||
| |message_desc=??? | |message_desc=A 1D pit object can be connected to a maximum of wjs??? 2D cells. | ||
| |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | |||
| |suggestions=???? | |||
| |discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | |discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | ||
| |link3='' | |link3='' | ||
Revision as of 12:09, 18 February 2011
TUFLOW Message 
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message 
NA
Message Type 
WARNING
Description 
A 1D pit object can be connected to a maximum of wjs??? 2D cells.
Suggestions 
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
| Up | 
|---|
|  2xxx Messages |