Difference between revisions of "TUFLOW Message 2239"

From Tuflow
Jump to navigation Jump to search
Line 10: Line 10:
 
|prelink=[[TUFLOW_Message_2238|Message 2238]]
 
|prelink=[[TUFLOW_Message_2238|Message 2238]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2302|Message 2302]]
+
|nextlink=[[TUFLOW_Message_2240|Message 2240]]
 
}}
 
}}

Revision as of 16:19, 5 October 2018

TUFLOW Message
WARNING 2239 - Mass balance tracking time-series records exceeded allocated limit of <number of time-series> - please contact support@tuflow.com.

Alternate Message
NA

Message Type
WARNING

Description
The array limit of mass balance records retained throughout the simulation is exceeded. This can occur if the ISIS timestep is not equal to half the TUFLOW timestep, or if using the adaptive time stepping option. Prior to Build 2012-05-AC, TUFLOW would stop with a “Should not be here” message.

Suggestions
None. A permanent fix to this issue is planned for a future release. Note that the mass balance summary presented at the end of the simulation may not be complete.


Up
Go-up.png 2xxx Messages