Difference between revisions of "TUFLOW Message 0048"
Jump to navigation
Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 0048 - No 1D WLLs and no 2D Cells found within Output Zone |alt_msg=NA |type=ERROR |message_desc= There are no active 2D cells or 1D...") |
|||
Line 9: | Line 9: | ||
|link3='' | |link3='' | ||
|link4='' | |link4='' | ||
− | |prelink=[[ | + | |prelink=[[TUFLOW_Message_0047|Message 0047]] |
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | |uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | ||
− | |nextlink=[[ | + | |nextlink=[[TUFLOW_Message_0051|Message 0051]] |
}} | }} |
Revision as of 14:14, 9 October 2018
TUFLOW Message
ERROR 0048 - No 1D WLLs and no 2D Cells found within Output Zone
Alternate Message
NA
Message Type
ERROR
Description
There are no active 2D cells or 1D WLLs in code area or output zone.
Suggestions
Ensure Check that the active domain and code is selecting cells. Ensure that the code boundary is set to 1 (ie, that the cells will be active), check that the defined domain and the code area overlap (use the 2d_dom_check and the 2d_code_check), also check that layers are in the same projection.
Up |
---|
0xxx Messages |