TUFLOW Message 1048: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=WARNING 1048 - For B or W channel <Channel ID> ignoring Number_of attribute value which is greater than 1. |alt_msg=NA |type=WARNING |mess..."
 
No edit summary
Line 10: Line 10:
|prelink=[[TUFLOW_Message_1045|Message 1045]]
|prelink=[[TUFLOW_Message_1045|Message 1045]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1049|Message 1059]]
|nextlink=[[TUFLOW_Message_1049|Message 1049]]
}}
}}

Revision as of 13:23, 15 October 2018

TUFLOW Message
WARNING 1048 - For B or W channel <Channel ID> ignoring Number_of attribute value which is greater than 1.

Alternate Message
NA

Message Type
WARNING

Description
The Number_of or No_of_Culverts attribute on the 1d_nwk file is not valid for bridge or weir channels. For the channel ID specified, a value of greater than 1 has been specified and is being ignored. For culverts this is the number of culvert barrels. For example a value of 3 would indicate three parallel culverts.

Suggestions
As this attribute is not used by TUFLOW for a bridge or weir type channel, for clarity it is recommended that the attribute be left at 0 or 1.


Up