Difference between revisions of "TUFLOW Message 2302"
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
|link3='' | |link3='' | ||
|link4='' | |link4='' | ||
− | |prelink=[[ | + | |prelink=[[TUFLOW_Message_2242|Message 2242]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2304|Message 2304]] | |nextlink=[[TUFLOW_Message_2304|Message 2304]] | ||
}} | }} |
Revision as of 16:25, 5 November 2020
TUFLOW Message
WARNING 2302 - Green Ampt solution may not have converged.
Alternate Message
NA
Message Type
WARNING
Description
The maximum number of iterations of the Green Ampt solution have been exceeded.
Suggestions
The number of iterations of the Green-Ampt infiltration convergence test have been exceeded. The number of iterations can be changed with the GA Maximum Iterations == command. The GA Convergence Value == command is used to set the convergence tolerance. Refer to the TUFLOW manual for more guidance on these commands.
Up |
---|
2xxx Messages |