===Outputs===
The following are output from the tool:
* Output point layer - an output log from the tool identifying
===Processing Options===
Line 18:
<li> '''Flow Area Check''' - will flag locations where the downstream flow area decreases.
<ul>
<li> % decrease - only relevant where more than one pipe is entering the downstream junction
</ul>
<li> '''Invert Check''' - will flag locations where
<li> '''Angle Check''' - will flag locations where the angle between the incoming pipe and outgoing pipe is less than the given input angle (180 deg is straight). Will only flag locations where this is true for all incoming and outgoing pipes at any given junction.
<li> '''Ground Cover Check''' - requires an input DEM. Will flag locations where the distance between the pipe obvert and ground elevation is less than the input threshold.
</ul>