Difference between revisions of "TUFLOW Message 1401"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1401 - Cannot connect Node with a X1DH link as the node is already connected to an external 1D domain via a X1DQ link. |alt_msg=NA |type=[[...")
 
Line 2: Line 2:
 
|tuflow_message=ERROR 1401 - Cannot connect Node with a X1DH link as the node is already connected to an external 1D domain via a X1DQ link.
 
|tuflow_message=ERROR 1401 - Cannot connect Node with a X1DH link as the node is already connected to an external 1D domain via a X1DQ link.
 
|alt_msg=NA
 
|alt_msg=NA
|type=[[WARNING]]
+
|type=[[ERROR]]
 
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH link, but the TUFLOW node is already connected to an external 1D node using a X1DQ link.
 
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH link, but the TUFLOW node is already connected to an external 1D node using a X1DQ link.
 
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one.
 
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one.

Revision as of 11:15, 7 October 2011

TUFLOW Message
ERROR 1401 - Cannot connect Node with a X1DH link as the node is already connected to an external 1D domain via a X1DQ link.

Alternate Message
NA

Message Type
ERROR

Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH link, but the TUFLOW node is already connected to an external 1D node using a X1DQ link.

Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one.


Up