TUFLOW Message
ERROR 1391 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.
Alternate Message
NA
Message Type
ERROR
Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node.
Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).