Difference between revisions of "TUFLOW Message 1401"

From Tuflow
Jump to navigation Jump to search
Line 8: Line 8:
 
|link3=''
 
|link3=''
 
|link4=''
 
|link4=''
|prelink=[[TUFLOW_Message_1381|Message 1381]]
+
|prelink=[[TUFLOW_Message_1394|Message 1394]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|nextlink=[[TUFLOW_Message_1991|Message 1991]]
 
|nextlink=[[TUFLOW_Message_1991|Message 1991]]
 
}}
 
}}

Revision as of 14:56, 7 October 2011

TUFLOW Message
ERROR 1401 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.

Alternate Message
NA

Message Type
ERROR

Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.

Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).


Up
Go-up.png 1xxx Messages