Difference between revisions of "TUFLOW Message 1401"
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
|link3='' | |link3='' | ||
|link4='' | |link4='' | ||
− | |prelink=[[ | + | |prelink=[[TUFLOW_Message_1394|Message 1394]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1991|Message 1991]] | |nextlink=[[TUFLOW_Message_1991|Message 1991]] | ||
}} | }} |
Revision as of 14:56, 7 October 2011
TUFLOW Message
ERROR 1401 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.
Alternate Message
NA
Message Type
ERROR
Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.
Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).
Up |
---|
1xxx Messages |