Difference between revisions of "TUFLOW Message 2306"

From Tuflow
Jump to navigation Jump to search
(Extra information on 0 WrF for older versions)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt>Wetting and Drying == ON Method B</tt>" which has been the default method since 2012-05 a non zero WrF must be specified.  For "<tt>Wetting and Drying == ON</tt>" or "<tt>Defaults == Pre 2012</tt>" a zero value could be used to locally turn off the weir function.
+
|message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON Method B</font></tt>" which has been the default method since 2012-05 a non zero WrF must be specified.  For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON</font></tt>" or "<tt><font color="blue">Defaults </font><font color="red">== </font><font color="black">Pre 2012</font></tt>" a zero value could be used to locally turn off the weir function.
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt>Read GIS WrF==, Set WrF==, Read RowCol WrF==</tt>.
+
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>.
 
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]]
 
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]]
 
|link3=''
 
|link3=''

Revision as of 11:39, 27 June 2022

TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.

Alternate Message
NA

Message Type
ERROR

Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "Wetting and Drying == ON Method B" which has been the default method since 2012-05 a non zero WrF must be specified. For "Wetting and Drying == ON" or "Defaults == Pre 2012" a zero value could be used to locally turn off the weir function.

Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF ==, Set WrF ==, Read RowCol WrF ==.


Up
Go-up.png 2xxx Messages