Difference between revisions of "TUFLOW Message 2306"
Jump to navigation
Jump to search
(Extra information on 0 WrF for older versions) |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt>Wetting and Drying == ON Method B</tt>" which has been the default method since 2012-05 a non zero WrF must be specified. For "<tt>Wetting and Drying == ON</tt>" or "<tt>Defaults == Pre 2012</tt>" a zero value could be used to locally turn off the weir function. | + | |message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON Method B</font></tt>" which has been the default method since 2012-05 a non zero WrF must be specified. For "<tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON</font></tt>" or "<tt><font color="blue">Defaults </font><font color="red">== </font><font color="black">Pre 2012</font></tt>" a zero value could be used to locally turn off the weir function. |
− | |suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt>Read GIS WrF==, Set WrF==, Read RowCol WrF==</tt>. | + | |suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>. |
|discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]] | |discussion_page=* [[Talk:TUFLOW Message 2306|Discuss Message 2306]] | ||
|link3='' | |link3='' |
Revision as of 11:39, 27 June 2022
TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.
Alternate Message
NA
Message Type
ERROR
Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For "Wetting and Drying == ON Method B" which has been the default method since 2012-05 a non zero WrF must be specified. For "Wetting and Drying == ON" or "Defaults == Pre 2012" a zero value could be used to locally turn off the weir function.
Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF ==, Set WrF ==, Read RowCol WrF ==.
Up |
---|
2xxx Messages |