TUFLOW Message 2140: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
* Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc) |
* Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc) |
||
<br> |
|||
|discussion_page=* [[Talk:TUFLOW Message 2140|Discuss Message 2140]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_2139|Message 2139]] |
|prelink=[[TUFLOW_Message_2139|Message 2139]] |
||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
Revision as of 11:06, 1 July 2022
TUFLOW Message
ERROR 2140 - Reading following line in control file.
Alternate Message
NA
Message Type
ERROR
Description
An error occurred reading the following line in the control file.
Suggestions
Check the line is a valid TUFLOW command for the version of TUFLOW that you are running. Common mistake are:
- Omitting the double equals (Set IWL = 0.6 not Set IWL == 0.6)
- Using the Read GIS syntax for versions of TUFLOW prior to 2010 (use Read MI instead).
- Using the Read RowCol syntax for versions of TUFLOW prior to 2010 (use Read MID instead).
- Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc)
Up |
---|
![]() |