TUFLOW Message 1315: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 5: Line 5:
|message_desc=Open channel (e.g. "S" type channel) is connected to 1D manhole (1d_mh) object. Manhole structures are only applicable when connected to culverts and pits. For more information on Manholes see Section 4.5.2 Manholes (Automatic and 1d_mh Layer) of the TULFOW manual (2010 version).
|message_desc=Open channel (e.g. "S" type channel) is connected to 1D manhole (1d_mh) object. Manhole structures are only applicable when connected to culverts and pits. For more information on Manholes see Section 4.5.2 Manholes (Automatic and 1d_mh Layer) of the TULFOW manual (2010 version).
|suggestions=Remove manhole object.
|suggestions=Remove manhole object.

|discussion_page=* [[Talk:TUFLOW Message 1315|Discuss Message 1315]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1314|Message 1314]]
|prelink=[[TUFLOW_Message_1314|Message 1314]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]

Revision as of 15:37, 5 July 2022

TUFLOW Message
ERROR 1315 - Open channel is connected to Manhole <manhole ID>. Only culverts and pits can be connected.

Alternate Message
NA

Message Type
ERROR

Description
Open channel (e.g. "S" type channel) is connected to 1D manhole (1d_mh) object. Manhole structures are only applicable when connected to culverts and pits. For more information on Manholes see Section 4.5.2 Manholes (Automatic and 1d_mh Layer) of the TULFOW manual (2010 version).

Suggestions
Remove manhole object.


Up
1xxx Messages