TUFLOW Message
WARNING 2124 - No 2D connection specified for pit or node.
Alternate Message
NA
Message Type
WARNING
Description
No 2D connection specified for pit. Usually indicates that the SX has been omitted or typed incorectly in the 1d_nwk GIS attribute Conn_2D
(previously Topo_ID).
Suggestions
Review pit to see if connection to the 2D model is intended, if so specify a valid connection type in the Conn_2D attribute.