Difference between revisions of "TUFLOW Message 2135"
Jump to navigation
Jump to search
Line 23: | Line 23: | ||
For Example:<br> | For Example:<br> | ||
[[File:ERROR 2135_002.JPG|500px]] | [[File:ERROR 2135_002.JPG|500px]] | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_2134|Message 2134]] | |prelink=[[TUFLOW_Message_2134|Message 2134]] | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2136|Message 2136]] | |nextlink=[[TUFLOW_Message_2136|Message 2136]] | ||
}} | }} |
Revision as of 13:39, 6 July 2022
TUFLOW Message
ERROR 2135 - Following command must occur within a Start/End 2D Domain block.
Alternate Message
NA
Message Type
ERROR
Description
Must use Start 2D Domain and End 2D Domain commands to specify multiple 2D domains. The mandatory .tcf commands that occur within a 2D domain block are:
BC Control File
Geometry Control File
Timestep
Optional commands that can be used are:
Cell Wet/Dry Depth
Cell Side Wet/Dry Depth
Set IWL
Read GIS FC
Read GIS GLO
Read GIS IWL
Read MID IWL
Read GIS LP
Read GIS PO
Instability Water Level
Suggestions
For multiple 2D domain model listed command must occur within Start/End 2D Domain block. Move the command to a specifc 2D domain.
Up |
---|
2xxx Messages |