TUFLOW Message 2215: Difference between revisions
		
		
		
		Jump to navigation
		Jump to search
		
Content deleted Content added
| No edit summary | No edit summary | ||
| Line 5: | Line 5: | ||
| |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | ||
| |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. | ||
| |discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] | |||
| |link3='' | |||
| |link4='' | |||
| |prelink=[[TUFLOW_Message_2214|Message 2214]] | |prelink=[[TUFLOW_Message_2214|Message 2214]] | ||
| |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
Revision as of 14:25, 6 July 2022
TUFLOW Message 
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message 
NA
Message Type 
WARNING
Description 
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions 
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.