Revision as of 15:21, 13 July 2022
TUFLOW Message
ERROR 3036: Hydrograph weight data not in range [0 ... 6.5535].
Alternate Message
None
Message Type
ERROR
Description
Hydrographs were not accepted by the HPC solver. Prior to 2020-10-AA release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.
Suggestions
Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.
If the above doesn't apply, please contact support@tuflow.com.
| Up |
|---|