TUFLOW Message
ERROR 3546 -

Alternate Message
WARNING 3546 -

Message Type
ERROR WARNING

Description
If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued.

Suggestions
Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used.