TUFLOW Message 3546: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3546 - |type=ERROR WARNING |alt_msg=WARNING 3546 - |message_desc= If SGS Materials are on in combination with depth varying Ma..." |
No edit summary |
||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 3546 - |
|tuflow_message=ERROR 3546 - SGS Materials is not supported in this build for models with depth varying Mannings n. |
||
|type=[[ERROR]] [[WARNING]] |
|type=[[ERROR]] [[WARNING]] |
||
|alt_msg=WARNING 3546 - The SGS Materials methodology has changed for the 2022 TUFLOW release and changes in results will occur. |
|||
|alt_msg=WARNING 3546 - |
|||
|message_desc= If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued. |
|message_desc= If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued. |
||
|suggestions=Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used. |
|suggestions=Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used and review results. |
||
|prelink=[[TUFLOW_Message_3543|Message 3543]] |
|prelink=[[TUFLOW_Message_3543|Message 3543]] |
||
Revision as of 14:27, 14 October 2022
TUFLOW Message
ERROR 3546 - SGS Materials is not supported in this build for models with depth varying Mannings n.
Alternate Message
WARNING 3546 - The SGS Materials methodology has changed for the 2022 TUFLOW release and changes in results will occur.
Description
If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued.
Suggestions
Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used and review results.
| Up |
|---|