(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0. |alt_msg=NA |type=ERROR |message_desc=????...') |
|||
(2 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m<sup>3</sup>/s is generated, and mass is created! |
− | |suggestions= | + | |suggestions=Ensure first values in inlet curve are 0,0 |
− | + | <br> | |
− | + | ||
− | |||
− | |||
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | |uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:10, 22 December 2022
TUFLOW Message
ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0.
Alternate Message
NA
Message Type
ERROR
Description
First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m3/s is generated, and mass is created!
Suggestions
Ensure first values in inlet curve are 0,0
Up |
---|
0xxx Messages |