TUFLOW Message 1092: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 4: Line 4:
|type=[[ERROR]]<br>
|type=[[ERROR]]<br>
[[WARNING]]
[[WARNING]]
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If '<font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012 </tt></font>' is set, a WARNING 1092 is issued and the model simulation will not stop.
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If <font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012 </tt></font> is set, a WARNING 1092 is issued and the model simulation will not stop.
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit.
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit.


|prelink=[[TUFLOW_Message_1091|Message 1091]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1093|Message 1093]]
}}
}}

Latest revision as of 15:09, 22 December 2022

TUFLOW Message
ERROR 1092 - No flow area provided for pit type ",a,".

Alternate Message
ERROR 1092 - Flow area provided for pit type or yQ curve "a" is less than or equal to zero.

Message Type
ERROR
WARNING

Description
Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1092 is issued and the model simulation will not stop.

Suggestions
Check for a null or less than or equal to zero flow area within a Q pit.


Up