Difference between revisions of "TUFLOW Message 1093"
Jump to navigation
Jump to search
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
|tuflow_message=ERROR 1093 - No entry width provided for pit type ",a,". | |tuflow_message=ERROR 1093 - No entry width provided for pit type ",a,". | ||
− | |alt_msg=ERROR 1093 - Entry width provided for pit type or yQ curve " | + | |alt_msg=ERROR 1093 - Entry width provided for pit type or yQ curve "b" is less than or equal to zero. |
|type=[[ERROR]]<br> | |type=[[ERROR]]<br> | ||
[[WARNING]] | [[WARNING]] | ||
− | |message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If | + | |message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If <font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012</tt></font> is set, a WARNING 1093 is issued and the model simulation will not stop. |
|suggestions=Check for a null or less than or equal to zero width within a Q pit. | |suggestions=Check for a null or less than or equal to zero width within a Q pit. | ||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | + | ||
}} | }} |
Latest revision as of 15:10, 22 December 2022
TUFLOW Message
ERROR 1093 - No entry width provided for pit type ",a,".
Alternate Message
ERROR 1093 - Entry width provided for pit type or yQ curve "b" is less than or equal to zero.
Description
Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1093 is issued and the model simulation will not stop.
Suggestions
Check for a null or less than or equal to zero width within a Q pit.
Up |
---|
1xxx Messages |