TUFLOW Message 1123: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
| (2 intermediate revisions by 2 users not shown) | |||
Line 5:
|message_desc=Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priority than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123.
|suggestions=Check channel and cross-section configuration, remove unwanted cross-section.<br>
If using end cross-sections ensure that the end of the 1d_nwk layer is snapped to a vertex on the cross-section. If this is not the case the cross-section may be treated as a mid cross-section. An example of where this may occur is shown in the schematic below.<br><br>
[[File:Error 1123.jpeg|800px]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
}}
| |||