TUFLOW Message 1214: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.

|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]]

|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1213|Message 1213]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1218|Message 1218]]
}}
}}

Latest revision as of 15:52, 22 December 2022

TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Message Type
ERROR,WARNING

Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).

Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.


Up
1xxx Messages