Revision as of 10:32, 23 December 2022
TUFLOW Message
ERROR 1332 - Conflicting flags for channel
Alternate Message
NA
Message Type
ERROR
Description
Conflicting channel flags encountered. For example a "F" flag is used to fix the structure losses, an "A" flag is used to set the structure losses to adjust. This flags are conflicting and cannot be combined.
For a detailed description of channel flags see Table 4.13 1D Channel and Node Types of the TUFLOW manual (2010 version).
Suggestions
Remove conflicting channel flags.