TUFLOW Message
ERROR 1333 - Invalid flag for channel <channel ID>: "A"

Alternate Message
NA

Message Type
ERROR

Description
The "A" flags is used to set the structure losses to adjust. This can only be used for a bridge or culvert channel, e.g. use 1D network type "CA" for a circular culvert with adjusted losses. This flag is invalid for other channel types.
This flag overrides that set with the global Structure Losses == ADJUST or FIX command.

Suggestions
Remove "A" flag from non-structure channel.