TUFLOW Message 1353: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 8: Line 8:
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.

|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1352|Message 1352]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1355|Message 1355]]
}}
}}

Latest revision as of 10:37, 23 December 2022

TUFLOW Message
ERROR 1353 - No NA data for Node <Node ID>

Alternate Message
ERROR 1353 - No CS data for Chan <Chan ID>

Message Type
ERROR

Description
If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.

Suggestions
Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.


Up