TUFLOW Message 1353: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1353 - No "//sec//" data for "//iprt, trim(aco(i)) |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |discussion_page=* [[Ta...'
 
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 1353 - No "//sec//" data for "//iprt, trim(aco(i))
|tuflow_message=ERROR 1353 - No NA data for Node <Node ID>
|alt_msg=ERROR 1353 - No CS data for Chan <Chan ID>
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).<br>
|message_desc=????
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.<br>
|suggestions=????
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.
|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]]
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
|link3=''
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.
|link4=''

|prelink=[[TUFLOW_Message_1352|Message 1352]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1355|Message 1355]]
}}
}}

Latest revision as of 10:37, 23 December 2022

TUFLOW Message
ERROR 1353 - No NA data for Node <Node ID>

Alternate Message
ERROR 1353 - No CS data for Chan <Chan ID>

Message Type
ERROR

Description
If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.

Suggestions
Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.


Up
1xxx Messages