Difference between revisions of "TUFLOW Message 1625"
Jump to navigation
Jump to search
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=CHECK 1625 - Unconnected pit | + | |tuflow_message=CHECK 1625 - Unconnected pit. |
− | |alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. | + | |alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use <font color="blue"><tt>PIT NO 1D CONNECTION </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>ERROR</tt></font>. |
|type=[[CHECK]] | |type=[[CHECK]] | ||
|message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>, and will be modelled as an 1D virtual pipe. | |message_desc=Pit is not snapped or within the <font color="blue"><tt>Pit Search Distance </tt></font> <font color="red"><tt>==</tt></font>, and will be modelled as an 1D virtual pipe. | ||
− | |suggestions=If the pit must be connected to a 1D channel, use the ECF command <font color="blue"><tt>Pit No 1D Connection </tt></font> <font color="red"><tt>==</tt></font> ERROR to force an error and check the pit connection. See also [[TUFLOW_Message_1626|ERROR 1626]]. | + | |suggestions=If the pit must be connected to a 1D channel, use the ECF command <font color="blue"><tt>Pit No 1D Connection </tt></font> <font color="red"><tt>==</tt></font> ERROR to force an error and check the pit connection. See also <u>[[TUFLOW_Message_1626|ERROR 1626]]</u>. |
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:49, 23 December 2022
TUFLOW Message
CHECK 1625 - Unconnected pit.
Alternate Message
CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR.
Message Type
CHECK
Description
Pit is not snapped or within the Pit Search Distance ==, and will be modelled as an 1D virtual pipe.
Suggestions
If the pit must be connected to a 1D channel, use the ECF command Pit No 1D Connection == ERROR to force an error and check the pit connection. See also ERROR 1626.