Difference between revisions of "TUFLOW Message 2013"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=2D cell has a zero or negative bed resistance coefficient (eg. a negative Manning's n). Note: TUFLOW Builds prior to August 2...') |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2013 - Zero or negative bed resistance coefficient found at |
+ | |alt_msg=NA | ||
+ | |type=[[ERROR]] | ||
|message_desc=2D cell has a zero or negative bed resistance coefficient (eg. a negative Manning's n). Note: TUFLOW Builds prior to August 2000 used default values of C=50, M=40 or n=0.025. | |message_desc=2D cell has a zero or negative bed resistance coefficient (eg. a negative Manning's n). Note: TUFLOW Builds prior to August 2000 used default values of C=50, M=40 or n=0.025. | ||
− | |suggestions= | + | |suggestions=Specify a positive bed resistance coefficient. |
− | + | ||
− | + | ||
− | + | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |
− | |||
− | | | ||
}} | }} |
Latest revision as of 10:55, 23 December 2022
TUFLOW Message
ERROR 2013 - Zero or negative bed resistance coefficient found at
Alternate Message
NA
Message Type
ERROR
Description
2D cell has a zero or negative bed resistance coefficient (eg. a negative Manning's n). Note: TUFLOW Builds prior to August 2000 used default values of C=50, M=40 or n=0.025.
Suggestions
Specify a positive bed resistance coefficient.
Up |
---|
2xxx Messages |