TUFLOW Message 2014: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=No active 2D cells within Source over Area (SA) inflow polygon. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 201...'
 
No edit summary
 
(5 intermediate revisions by 3 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=????ERROR 2014 - No active cells within SA inflow polygon.
|alt_msg=NA
|message_desc=No active 2D cells within Source over Area (SA) inflow polygon.
|type=[[ERROR]]
|suggestions=????
|message_desc=No active 2D cells within Source over Areaarea (SA) inflow polygon.
|discussion_page=* [[Talk:TUFLOW Message 2014|Discuss Message 2014]]
|suggestions=Source area polygon is outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended. Check the code polygon has active cells (attribute of 1).
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2013|Message 2013]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2015|Message 2015]]
}}