Difference between revisions of "TUFLOW Message 2062"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
|suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. | |suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. | ||
− | + | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 11:54, 23 December 2022
TUFLOW Message
ERROR 2062 - SC connection cannot connect to a HX line.
Alternate Message
NA
Message Type
ERROR
Description
Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object.
Suggestions
SC line should only be used with SH boundary object. For SX and HX connections use CN objects.
Up |
---|
2xxx Messages |