Line 3:
|alt_msg=ERROR 2070 - Same rainfall gauge applied to 2D cell more than once.
|type=[[ERROR]]
|message_desc=This ERROR message has two variations: one which states that more than one (different) rainfall gauges have been applied to a single cell, and the other which states that the same (duplicate) rainfall gauges have been applied to a single cell.
|suggestions= For the first "more than one rainfall gauges" ERROR, the message tells the user that overlapping RF polygons referencing '''different''' hyetographs has been assigned to an individual cell. This
<br>
For the second "same rainfall gauge" ERROR, the message tells the user that overlapping RF polygons referencing the '''same''' hyetograph has been assigned to an individual cell. The message is warning the user that the rainfall has been duplicated. In this scenario, setting <br><font color="blue"><tt>Rainfall Gauges </tt></font> <font color="red"><tt>==</tt></font><tt> Unlimited per Cell </tt>will not suppress the warning. Instead, the user must check for overlapping polygons and amend where necessary to remove the ERROR. Note that if the common boundary of two adjacent polygons falls on a cell centre (ZC point), this ERROR message may be outputted.